| Subject : |
|
KN2116A 404 Object not found when connecting via Browswer |
| |
| Description : |
|
There is always 404 Object Not Found error, when connecting via Internet Explorer or other browser. |
| |
| Solution : |
|
Please check the Login String setting. Login String entry field lets the super administrator specify a login string (in addition to the IP address) that users must add to the IP address when they access the KVM Over the NET™ switch with a browser. For example, if 192.168.0.126 were the IP address, and abcdefg were the loginstring, then the user would have to key in:"http://192.168.0.126/abcdefg". |
| |