News
FAQ Search icon_logout FAQ View
 
Subject : 
KVM over IP not working
 
Description : 
Hi,
We are unable to access the KVM switch from within the intranet. We are trying to access it using the URL, we are able to ping the IP address but when we try to access it from the browser we get a gateway timed out message. There are no firewalls within the intranet. Could you please advise as to what should be done for us to enable access of the same?
Thanks,
Dash
 
Solution : 
Dear Customer:
Please follow below steps for testing:
1. Please use a crossover cable connect between your PC and KN2108.
2. Try to ping the KN2108 IP address and it should be get response.
3. Try to access it by browser, it should be display login screen.
4. If you can login KN2108 by this configuration, your KN2108 should be no problem. Please try to check your intranet environment.
The KN2108 default will use below TCP/IP port number:
80 --> browser
443 --> SSL
9000 --> Windows client/Admin tool
9001 --> Log server
9002 --> Java client
Jason Chen
 
Related FAQ : 
US421's FAQ(switching function)
KN9116's Basic FAQ (Hotkey"F12",ArrayMode,Mouse Cursors issue)
CS64U Hotkey combination to switch ports
Establish a certificate on ATEN KVM over IP switch
Winclient is unable to connect to KL9108 under Windows 10
 

Was this information helpful? Y   N  
Any Comment? 
Thank you for your valueable comment!!!!
 
Still need more assistance?