News
FAQ Search icon_logout FAQ View
 
Subject : 
CS1842/CS1844/CS1942DP/CS1944DP LED keeps blinking issue
 
Description : 
The LED of the CS1842/CS1844/CS1942DP/CS1944DP keeps blinking, the keyboard and mouse can work, but the button cannot switch the port, what is the reason?
 
Solution : 
The CS1842/CS1844/CS1942DP/CS1944DP supports Quad-Display mode that connecting two dual display KVM as one Quard display KVM,in this mode the two CS1842/CS1844/CS1942DP/CS1944DP one should be Primary, another should be secondary 
This issue is because  CS1842/1844/CS1942DP/CS1944DP is under the secondary mode
Detail information could refer "Quad-Display (DCC Mode)" of manual of CS1842/CS1844/CS1942DP/CS1944DP that can download from :
CS1842/CS1844:
https://www.aten.com/global/en/supportcenter/downloads/?q=CS1842
CS1942DP/CS1944DP :
https://www.aten.com/global/en/supportcenter/downloads/?q=CS1942DP
Anyhow, please make sure the DCC switch on the rear side of CS18242/1844/CS1942DP/CS1944DP is on "P" (Primary) then your device should work fine. Better change the DCC switch by follows step:
Remove KVM power --> setup KVM mode --> power on KVM.
If the issue persists, please contact our Tech Support for assistance.
 
Related FAQ : 
Can not upgrade FW by port 1 under Win 10
CS1942DP / Boundless Switch
Invoke HSM without NUM-key
Availability between SN0132/SN0148 & SN0108/SN0116
CN8000 - IP
 

Was this information helpful? Y   N  
Any Comment? 
Thank you for your valueable comment!!!!
 
Still need more assistance?