News
FAQ Search icon_logout FAQ View
 
Subject : 
CN6000 Cannot connect with java client
 
Description : 
A have a CN-6000 with the last upgrade (1.6.152) and I cannot connect with the java client.
I have always the message 'Invalid Server Adress' over the windows Java Client 1.6.152
I had the same problem when I buy this hardware with the version 1.6.148
I have JRE 1.4.2-11
I have also checked 'java client' and 'windows client' in the 'User Manager'
It's work fine with windows client.
What can I do ?
 
Solution : 
Since Java script does not support the filter function, we add a "Default Java page name" function in the "Security" section to strengthen the CN6000's security ability!!
If there is no any word in the "Default Java page name" column, the CN6000 can not be accessed with the Java Client!!
When there are some words in the "Default Java page name" column, for example "abc123", and the IP address of the CN6000 is 192.168.100.200, you MUST access to the CN6000 by the address: 192.168.100.200/abc123
 

Was this information helpful? Y   N  
Any commend for this FAQ? 
Thank you for your valueable comment!!!!
 
If you need more assistance, please click the button on the right (Ask Question) and one of our experts will help you