VE89系列RS-232連接腳位
 
Description : 
我想將VE8900T跟VE8900R當成我電腦跟螢幕之間RS-232通訊的路徑。
我已經將設定設好成follow video path也連接了RS-232的線,但並不能讓通訊成功。
請問兩端的腳位是一樣的嗎?
I want to make a RS-232 path to send the command from the PC connected to VE8900T to monitor connected to VE8900R.
When I set follow video path and connect the RS232 cable, I couldn't make it work.
Are the pin assignment different on both side?
 
Solution : 
請將VE8900T的腳位照以下方式連接:
T--->2
R--->3
G--->5
再將VE8900R的腳位照以下方式連接:
T--->3
R--->2
G--->5
 