Home
Log In
Language:
简体中文
繁體中文
English
日本語(日本)
한국어(대한민국)
Deutsch
Français
Italiano
Português
Español
русский
News
FAQ Search
FAQ View
Subject :
VE89系列RS-232連接腳位
Description :
我想將VE8900T跟VE8900R當成我電腦跟螢幕之間RS-232通訊的路徑。
我已經將設定設好成follow video path也連接了RS-232的線,但並不能讓通訊成功。
請問兩端的腳位是一樣的嗎?
I want to make a RS-232 path to send the command from the PC connected to VE8900T to monitor connected to VE8900R.
When I set follow video path and connect the RS232 cable, I couldn't make it work.
Are the pin assignment different on both side?
Solution :
請將VE8900T的腳位照以下方式連接:
T--->2
R--->3
G--->5
再將VE8900R的腳位照以下方式連接:
T--->3
R--->2
G--->5
Related FAQ :
其他安全验证
CCVSR 로그인 할 수 없습니다.
CL5800 - 直接接计算机
KN4132 外部認證支援
OSDの画面を表示している時にCapsLockのLEDが点灯しない(CS18208/CS18216/CS19208/CS19216)
Was this information helpful?
Y
N
Any commend for this FAQ?
Submit Comment
Thank you for your valueable comment!!!!
If you need more assistance, please click the button on the right (Ask Question) and one of our experts will help you
Ask Question
Account
Membership Function
Log In
Create New
Support Center
Technical Support
FAQ
Ask Question
ATEN Hotkey List
3rd-Party Device Compatible List
Service Support
Warranty Policy
Repair Query
Product Registration
Product Information
Windows Compatible Product List
Discontinued Products
Downloads
|
eService System FAQ
|
© ATEN INTERNATIONAL Co., Ltd. All rights reserved.